Galvanometer and Direction of Current

A galvanometer is used to detect small electric currents and identify their direction in an electrical circuit. The direction of current is determined by observing the movement of the pointer on the galvanometer scale.

A centre-zero galvanometer can indicate current flowing in either direction. When the current reverses, the pointer deflects towards the opposite side of the zero position. This feature makes it useful for detecting changes in current direction in electrical circuits.

Table of Contents

How Does a Galvanometer Show the Direction of Current?

A galvanometer indicates the direction of current through the direction of pointer deflection.

A centre-zero galvanometer has its zero marking at the middle of the scale, allowing the pointer to move both left and right.

  • Right deflection: Indicates current flowing in the reference direction.
  • Left deflection: Indicates current flowing in the reverse direction.
  • Zero deflection: Indicates that no current is flowing through the galvanometer, assuming the instrument is correctly adjusted.

The actual direction represented by left or right deflection depends on the polarity of the galvanometer connections.

Direction of Deflection in Galvanometer (Centre-Zero Galvanometer)

A centre-zero galvanometer is specifically designed to detect current flowing in both directions. Its scale has zero at the centre, with positive and negative readings on opposite sides.

The direction of deflection in a galvanometer depends on the direction of current flowing through its moving coil.

  • Right-side deflection: When current flows in the reference direction, the pointer moves towards the right side of the zero position.
  • Left-side deflection: When the current direction is reversed, the pointer moves towards the left side.
  • Zero deflection: When no current flows through the coil, the pointer remains at the zero position.

The direction of pointer movement depends on the polarity of the galvanometer connections. Reversing the connections reverses the direction of deflection.

This arrangement helps identify both the presence and direction of current without changing the measuring instrument.

Effect of Reversing Current on Galvanometer Deflection

Reversing the current through a galvanometer reverses the direction of pointer movement.

Consider a galvanometer connected to a DC source:

  1. When the positive terminal of the source is connected to the positive terminal of the galvanometer, the pointer deflects towards one side.
  2. When the source connections are reversed, the current flows in the opposite direction.
  3. The pointer consequently deflects towards the opposite side of the zero position.

This observation confirms that the direction of pointer deflection depends on the direction of current flowing through the galvanometer coil.

Role of Fleming’s Left-Hand Rule

Fleming’s left-hand rule can be used to determine the direction of force acting on a current-carrying conductor placed in a magnetic field.

According to this rule:

  • Forefinger indicates the direction of the magnetic field.
  • Middle finger indicates the direction of conventional current.
  • Thumb indicates the direction of force.

When the current direction is reversed, the direction of force also reverses. This changes the direction of torque acting on the galvanometer coil, causing the pointer to move towards the opposite side.

Can a Galvanometer Detect the Direction of AC?

A conventional moving coil galvanometer is primarily designed for DC measurements.

In an AC circuit, the current continuously changes its direction. Consequently, the torque acting on the galvanometer coil also reverses periodically.

At normal AC frequencies, the pointer cannot follow these rapid changes. The average torque over a complete cycle is approximately zero, so the instrument does not produce a steady deflection.

Therefore, a conventional moving coil galvanometer is suitable for detecting the direction of DC current but is not suitable for directly indicating the direction of alternating current.

Conclusion

A galvanometer indicates the direction of electric current through the direction of pointer deflection. In a centre-zero galvanometer, current flowing in opposite directions produces deflection on opposite sides of the zero position. This characteristic makes it possible to identify current reversal and determine the direction of DC current in an electrical circuit.

Read Next:

  1. Conversion of Galvanometer into Voltmeter: Formula, Derivation and Working
  2. Conversion of Galvanometer into Ammeter – Formula, Circuit Diagram and Derivation
  3. Applications of Galvanometer
  4. Galvanometer: Definition, Working Principle, Construction and Working
  5. Sensitivity of Galvanometer: Formula, Types, Factors and Explanation
  6. Figure of Merit of a Galvanometer: Formula, Experiment and Calculation
  7. Galvanometer Resistance: Formula, Calculation and Measurement
  8. Moving Coil Galvanometer: Principle, Construction, Working, Diagram, Formula Derivation
  9. Galvanometer Constant: Formula, Derivation, Definition and Significance

Leave a comment